ElectricMotorCalculator

DC Motor Speed and Torque Calculator

Calculate rotational shaft speed (N = 60·Eb / 2π·Ke), electromagnetic torque (T = Kt·Ia), and mechanical power for permanent magnet and separately excited DC machines.

Motor Electrical & Machine Constants

Volts (V)
Ω (Ohms)
Amperes (A)
N·m / A

In coherent SI units, Ke [V·s/rad] equals Kt [N·m/A].

Speed & Torque Dynamic Outputs

Rotational Shaft Speed (N)
2101RPM(220.0 rad/s)

No-load theoretical speed: 2292 RPM

Electromagnetic Developed Torque (T)
0.50N·m(0.369 lb-ft)

Stall torque: 6.0 N·m (Stall current: 60 A)

Generated Back-EMF (Eb)
22.0Volts
Developed Power (P_mech)
110.0Watts
Calculation Step Audit
E_b = 24.0 V − (5.0 A × 0.40 Ω) = 22.0 V omega = 22.0 V / 0.100 (V·s/rad) = 220.0 rad/s Speed = (220.0 × 60) / (2π) = 2100.8 RPM Torque = 0.100 N·m/A × 5.0 A = 0.500 N·m (0.369 lb-ft) P_dev = 0.500 N·m × 220.0 rad/s = 110.0 W (0.110 kW) Stall = 24.0 V / 0.40 Ω = 60.0 A -> Stall Torque = 6.00 N·m

Governing Equations for Permanent Magnet & Shunt DC Motors

In direct current machines with constant field flux Φ (such as permanent magnet DC motors and constant-voltage shunt motors), shaft speed and mechanical torque are linearly governed by armature voltage and current:

Torque Equation: T = Kt × Ia

Electromagnetic torque is directly proportional to armature current. Kt is the torque constant in Newton-meters per ampere (N·m/A).

Speed Equation: ω = Eb / Ke

Shaft speed is proportional to back-EMF (Eb = Va − Ia·Ra). In coherent SI units, Ke [V·s/rad] = Kt [N·m/A].

Worked Example: 12V DC Motor Calculation (Speed, Current & Torque)

Consider a typical 12 V Permanent Magnet DC motor with an armature resistance of Ra = 0.5 Ω, operating under a running current of Ia = 2.0 A, and a motor torque constant of Kt = 0.02 N·m/A:

1. Back-EMF: Eb = Va − (Ia × Ra) = 12.0 V − (2.0 A × 0.50 Ω) = 11.0 Volts
2. Angular Vel: ω = Eb / Ke = 11.0 V / 0.02 (V·s/rad) = 550.0 rad/s
3. Shaft Speed: N = (550.0 × 60) / (2π) ≈ 5,252 RPM
4. Output Torque:T = Kt × Ia = 0.02 N·m/A × 2.0 A = 0.040 N·m (0.0295 lb-ft)
5. No-Load Speed:N_0 = (12.0 / 0.02) × 9.5493 ≈ 5,730 RPM
6. Stall Current:I_stall = 12.0 V / 0.50 Ω = 24.0 Amperes (Stall Torque = 0.48 N·m)

Frequently Asked Questions — DC Motor Speed & Torque

What is the formula of a DC motor for speed and torque?▼

The governing formulas are: (1) Terminal Voltage: Va = Eb + Ia·Ra, (2) Back-EMF: Eb = Va − Ia·Ra, (3) Rotational Speed: RPM = 9.5493 × (Va − Ia·Ra) / Ke, and (4) Electromagnetic Torque: T = Kt × Ia. In consistent SI units, Kt [N·m/A] = Ke [V·s/rad].

How many amps does a 12V DC motor draw?▼

Current draw depends heavily on motor power and shaft load: (1) Small hobby motors draw 0.1 A to 0.5 A no-load, and 1 A to 3 A under load. (2) Mid-size 12V motors (power tools, automotive wiper motors) typically draw 2 A to 5 A running, and 10 A to 20 A peak. (3) High-power 12V winches or starter motors draw 80 A to 250+ A, with stall inrush exceeding 300 A.

How to calculate the RPM and no-load speed of a DC motor?▼

At no-load, current is near zero, so back-EMF approximately equals supply voltage (Eb ≈ Va). No-load speed is N_0 = (60 × Va) / (2π × Ke). Under load, subtract the armature resistance voltage drop (Ia·Ra) to find actual operating speed: N = 9.5493 × (Va − Ia·Ra) / Ke. If the motor's velocity constant Kv (RPM/V) is known, speed is simply RPM = Kv × Eb.

How many RPM is a typical 12V DC motor?▼

Un-geared 12V permanent-magnet DC motors typically spin between 3,000 RPM and 12,000 RPM (micro-spindle motors can exceed 20,000 RPM). Geared motors with planetary or spur reduction stages commonly operate between 10 RPM and 600 RPM.

What are the four types of DC motors?▼

The four classic types are: (1) Permanent Magnet DC (PMDC), (2) Shunt-wound (parallel field circuit), (3) Series-wound (high starting torque, series field), and (4) Compound-wound (combining series and shunt field characteristics).

Which DC motor is the fastest?▼

Brushless DC (BLDC) and slotless coreless DC motors achieve the highest operational speeds, frequently operating between 40,000 RPM and 100,000+ RPM in medical handpieces and dental drills. Among brushed motors, series motors reach the highest speeds when lightly loaded.

Can a DC motor get weak over time?▼

Yes. Common causes of torque loss include carbon brush wear, brush spring tension relaxation, commutator carbon contamination or pitting, thermal demagnetization of permanent magnets caused by overheating, and winding insulation degradation.